Even an innovative system like the Fronius GEN24 constantly needs new impulses for improvement. As of now, the Primo and Symo series are available with the storage connection still deactivated at the factory. You decide for yourself whether and when you want to use this function by means of an activation code. Of course, they will continue to receive the familiar version with already enabled battery port - distinguishable by the "plus" after the GEN24 in the device name. The smart PV-Point emergency power connection with a maximum output power of 3 kW is active in every version. All other functions and interfaces remain proven good.
Technical Specifications: |
||
|---|---|---|
| Topology | : | transformerless |
| Charging current (A) | : | 12.50 |
| Max. short circuit current per MPPT (A) | : | 20 |
| Start input voltage (V) | : | 80 |
| Min. temperature ambient (°C) | : | -25 |
| Backup system light | : | no |
| Protection degree | : | IP66 |
| Number of independent MPPT (pcs) | : | 2 |
| Max. short circuit current (A) total | : | 40.00 |
| Backup system full | : | no |
| Arc Fault Circuit Interrupter | : | no |
| Surge protection AC | : | type 3 |
| Max. input voltage DC (V) | : | 1000.00 |
| Charging voltage (V) | : | 160-531 |
| Degree of protection IP | : | IP66 |
| Interface 1 | : | RS485 |
| Feed-in phases | : | 3 |
| AC nominal power (kW) | : | 5.00 |
| European efficiency (%) | : | 97.50 |
| Battery Connection | : | AC/DC |
| Step-Up converter | : | yes |
| Display | : | w/o display |
| Decibel | : | 36 |
| MPP min. voltage range input (V) | : | 80.00 |
| Max. efficiency (%) | : | 98.20 |
| DC connection | : | spring-type terminal |
| Integrated DC switch | : | yes |
| Min. voltage range input (V) | : | 80 |
| MPP max. voltage range input (V) | : | 800.00 |
| Total number of string inputs | : | 3 |
| Max. output current (A) | : | 7.60 |
| Surge protection DC | : | type 2 |
| Max. input current DC (A) total | : | 25.00 |
| Contact ripple control receiver | : | yes |
| Max. AC power (kVA) | : | 5.00 |
| Interface 2 | : | Ethernet |
| Contact for self-consumption optimization (e.g. for heat pump) | : | 4 |
| Max. generator power DC (kWp) | : | 7.50 |
| Max. input current per MPPT (A). | : | 12,5/12,5 |
| L * W * H Without Packaging (mm) | : | 530.00 * 474.00 * 165.00 |
| Product warranty (yr) | : | 2 |
Product Information
Product Information
Shipping & Returns
Shipping & Returns

SYMO GEN24 5.0
SYMO GEN24 5.0
Even an innovative system like the Fronius GEN24 constantly needs new impulses for improvement. As of now, the Primo and Symo series are available with the storage connection still deactivated at the factory. You decide for yourself whether and when you want to use this function by means of an activation code. Of course, they will continue to receive the familiar version with already enabled battery port - distinguishable by the "plus" after the GEN24 in the device name. The smart PV-Point emergency power connection with a maximum output power of 3 kW is active in every version. All other functions and interfaces remain proven good.
Technical Specifications: |
||
|---|---|---|
| Topology | : | transformerless |
| Charging current (A) | : | 12.50 |
| Max. short circuit current per MPPT (A) | : | 20 |
| Start input voltage (V) | : | 80 |
| Min. temperature ambient (°C) | : | -25 |
| Backup system light | : | no |
| Protection degree | : | IP66 |
| Number of independent MPPT (pcs) | : | 2 |
| Max. short circuit current (A) total | : | 40.00 |
| Backup system full | : | no |
| Arc Fault Circuit Interrupter | : | no |
| Surge protection AC | : | type 3 |
| Max. input voltage DC (V) | : | 1000.00 |
| Charging voltage (V) | : | 160-531 |
| Degree of protection IP | : | IP66 |
| Interface 1 | : | RS485 |
| Feed-in phases | : | 3 |
| AC nominal power (kW) | : | 5.00 |
| European efficiency (%) | : | 97.50 |
| Battery Connection | : | AC/DC |
| Step-Up converter | : | yes |
| Display | : | w/o display |
| Decibel | : | 36 |
| MPP min. voltage range input (V) | : | 80.00 |
| Max. efficiency (%) | : | 98.20 |
| DC connection | : | spring-type terminal |
| Integrated DC switch | : | yes |
| Min. voltage range input (V) | : | 80 |
| MPP max. voltage range input (V) | : | 800.00 |
| Total number of string inputs | : | 3 |
| Max. output current (A) | : | 7.60 |
| Surge protection DC | : | type 2 |
| Max. input current DC (A) total | : | 25.00 |
| Contact ripple control receiver | : | yes |
| Max. AC power (kVA) | : | 5.00 |
| Interface 2 | : | Ethernet |
| Contact for self-consumption optimization (e.g. for heat pump) | : | 4 |
| Max. generator power DC (kWp) | : | 7.50 |
| Max. input current per MPPT (A). | : | 12,5/12,5 |
| L * W * H Without Packaging (mm) | : | 530.00 * 474.00 * 165.00 |
| Product warranty (yr) | : | 2 |
Original: $2,295.46
-65%$2,295.46
$803.41Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Even an innovative system like the Fronius GEN24 constantly needs new impulses for improvement. As of now, the Primo and Symo series are available with the storage connection still deactivated at the factory. You decide for yourself whether and when you want to use this function by means of an activation code. Of course, they will continue to receive the familiar version with already enabled battery port - distinguishable by the "plus" after the GEN24 in the device name. The smart PV-Point emergency power connection with a maximum output power of 3 kW is active in every version. All other functions and interfaces remain proven good.
Technical Specifications: |
||
|---|---|---|
| Topology | : | transformerless |
| Charging current (A) | : | 12.50 |
| Max. short circuit current per MPPT (A) | : | 20 |
| Start input voltage (V) | : | 80 |
| Min. temperature ambient (°C) | : | -25 |
| Backup system light | : | no |
| Protection degree | : | IP66 |
| Number of independent MPPT (pcs) | : | 2 |
| Max. short circuit current (A) total | : | 40.00 |
| Backup system full | : | no |
| Arc Fault Circuit Interrupter | : | no |
| Surge protection AC | : | type 3 |
| Max. input voltage DC (V) | : | 1000.00 |
| Charging voltage (V) | : | 160-531 |
| Degree of protection IP | : | IP66 |
| Interface 1 | : | RS485 |
| Feed-in phases | : | 3 |
| AC nominal power (kW) | : | 5.00 |
| European efficiency (%) | : | 97.50 |
| Battery Connection | : | AC/DC |
| Step-Up converter | : | yes |
| Display | : | w/o display |
| Decibel | : | 36 |
| MPP min. voltage range input (V) | : | 80.00 |
| Max. efficiency (%) | : | 98.20 |
| DC connection | : | spring-type terminal |
| Integrated DC switch | : | yes |
| Min. voltage range input (V) | : | 80 |
| MPP max. voltage range input (V) | : | 800.00 |
| Total number of string inputs | : | 3 |
| Max. output current (A) | : | 7.60 |
| Surge protection DC | : | type 2 |
| Max. input current DC (A) total | : | 25.00 |
| Contact ripple control receiver | : | yes |
| Max. AC power (kVA) | : | 5.00 |
| Interface 2 | : | Ethernet |
| Contact for self-consumption optimization (e.g. for heat pump) | : | 4 |
| Max. generator power DC (kWp) | : | 7.50 |
| Max. input current per MPPT (A). | : | 12,5/12,5 |
| L * W * H Without Packaging (mm) | : | 530.00 * 474.00 * 165.00 |
| Product warranty (yr) | : | 2 |